Features

CT clamp structure

Features

Detection of current, leakage current, transformation ratio, higher harmonic current, phase, electrical energy, power, power factor, etc. of high and low voltage lines

Output method

Current sense output

Jaw size

Φ50mm

Secondary development Display window

46*30mm

Range

AC 0.0mA~1200A

Resolution

AC 0.1mA

Accuracy

±1.0%FS (50Hz/60Hz; 23℃±2℃) The wire is in the center of the jaw

Phase error

≤3°(50Hz/60Hz; 23℃±2℃)

Turns ratio

4000:1

Reference load

RL: 0~10A≤50Ω; 0~100A≤5Ω; 0~1200A≤0.5Ω

Quality

300g

Dimensions

Width, thickness and height 87*37*262mm

Output Interface

10cm long, open the upper and lower covers to connect

Electric field disturbance

When the external electric field 100A is close to 30mm, it is about 10mA

Wire position

The lead under test is in the center of the jaws

Current frequency

45Hz~65Hz (current frequency to be measured)

Line voltage

AC 60kV and below line test (the telescopic insulating rod should be fully opened)

Operating temperature

-25º C to +55º C

Medium strength

AC3700V/rms (between core and shell)

Current frequency

45Hz~65Hz (current frequency to be measured)