Products

Let the world use good meters

ES3090 Loop Resistance Tester

Please enable JavaScript in your browser to complete this form.

model

ES3090

ES3090E

Maximum test current

100A

220A

Remark

 

Currents above 100A only support fast mode

Function

Various contact resistance tests such as high-voltage switches and high-voltage circuit breakers; connection resistance tests of metal welded components; various loop resistance tests such as metal conductors; precision micro-ohm resistance tests

power supply

Built-in: 11.1 V 4000mAh rechargeable lithium battery

test method

four-wire method

charger

14.8 V charger

display mode

5.6-inch industrial-grade high-brightness color LCD screen

test interface

I+ (positive current), I- (negative current), U+ (positive voltage), U – (negative voltage)

Current output

Coarse adjustment gear: ≤5A, 10A, 30A, 50A, 80A, 100A, 200A, 220A

 

Thin strip gear: step value 2.5A, up to 87 gears of current

Measuring range

≤5A:  100μΩ~3500mΩ

 

10A:  20.0μΩ~200mΩ

 

30A  :  10.0μΩ~20.0mΩ

 

50A  :  2.00μΩ~15.0mΩ

 

80A  :  1.00μΩ~10.00mΩ

 

100A :  0.10μΩ~5.00mΩ

 

200A:  0.10μΩ~600uΩ

 

220A:  0.10μΩ~500uΩ

Minimum resolution

0.01μΩ

Test accuracy

±(reading×0.15% +0.5μΩ)

testing time

≤100A: Fast (recommended), 10s, 20s, 30s, 40s, 50s, 60s

>100A:Fast Mode

data storage

999 sets of data can be stored

Instrument size

Approx. 229 mm (length) × 166 mm (width) × 74 mm (height)

quality

Instrument weight: about 2kg

Test line

Standard length: 3m

 

The current and voltage test lines are tapped at both ends. The wiring is simple and the resistance is less than 10mΩ.

Data deletion

Select the format memory option in the settings interface to delete all data

Data review

Enter the data review interface and press the up, down, left and right keys to browse the stored data.

Automatic shut-down

have

battery voltage

There is a battery power indicator on the instrument corner.

backlight

Backlight adjustable brightness

Working current

The operating current under non-test conditions is 200 mA

 

The working current can be set by yourself in the test state.

circuit protection

With open circuit protection, overheating protection, etc.

temperature protection

The instrument is equipped with temperature monitoring

Working temperature and humidity

-10℃~40℃; below 70%RH, no condensation

Storage temperature and humidity

-20℃~60℃; below 70%RH

Suitable for safety regulations

IEC61010-1, CAT III 600V, pollution level 2, JJG166-1993 “Verification Procedures for DC Resistors”, “DL/T967-2005 Loop Resistance Tester and DC Resistance Rapid Tester Calibration Regulations》

ES3090 Loop Resistance Tester